Product Features
■ Adopted the photoelectric sensors which imported from America, and owned the proprietary intellectual property rights.
■ Differential photoelectric sensor for accurate detection of motor rotor position, good linearity, lower drift, high resolution and repeat positioning.
■ Adopted MM3D/Marking Mate 3D software system to support a variety of file formats, vector, bitmap and text bar code import, which is easy to learn and operate.
■ Maximum working range 1200×1200mm, it is customizable for any printing field from 300×300mm to 1200mm×1200mm.
■ Accurate load design for 30 mm mirrors, high accuracy of motor assembly, reasonable structure, very small static friction coefficient and zero offset, all ensured the best dynamic characteristics for the whole system.
■ Drives with advanced detection ability of position and speed, greatly improved the dynamic response performance and scanning speed of the whole system.
■ The whole system adopted the optimization Designing of electromagnetic compatibility, with high signal-to-noise ratio and strong anti-interference ability.
■ This scanner system solved the common problems of motor temperature drift, signal interference and zero drift, etc.
Technical Parameters
| Laser Type | 10600nm RF CO2 laser source | |
| Printing Field | 300×300mm~1200×1200mm | |
| Input Beam Size | 2.5~3mm | |
| X&Y Axes Mirrors Aperture Size | 30mm | |
| Speed | ||
| Marking Speed | 1000mm/s | |
| Positioning Speed | 1000mm/s | |
| Writing Speed | 125cps | |
| Step Response Time(1% of full scale) | 940us | |
| Step Response Time(10% of full scale) | 1500us | |
| Tracking Error Time | ≤440us | |
| Precision and Error | ||
| Linearity | 99.9% | |
| Repeatability (RMS) | <8μRad | |
| Gain Error | <5mRad | |
| Zero Offset | <5mRad | |
| Long-term Drift Over 8 Hours | <0.5mRad | |
| Scale Drift | <40PPM/℃ | |
| Zero Drift | <15μRad/℃ | |
| Power and Signal | ||
| Input Voltage | ±24VDC | |
| Rated Current | 4A | |
| Interface Signal | Digital: XY2-100 | |
| Machinery Scan Angle | ±12.5° | |
| Working Current, Temperature, Dimension | ||
| Working Temperature | 0℃~45℃ | |
| Storage Temperature | -10℃~60℃ | |
| Galvanometer Scanner Dimension | 556.5×158×188mm (L×W×H) | |
| Galvanometer Scanner Weight | ≈16.78Kg | |
| Water-Cooling System | ||
| Water Temperature | 25±3℃ | |
| Maximum water pressure | <3bar | |
| Water flow | >1L/min | |
| Water pipe specification | Outer diameter φ6mm Inner diameter φ4mm | |
Keywords: RF8330-3D-1200 Dynamic Focusing System
RF8330-3D-1200 Dynamic Focusing System
Contact us
Classification
Product Features
■ Adopted the photoelectric sensors which imported from America, and owned the proprietary intellectual property rights.
■ Differential photoelectric sensor for accurate detection of motor rotor position, good linearity, lower drift, high resolution and repeat positioning.
■ Adopted MM3D/Marking Mate 3D software system to support a variety of file formats, vector, bitmap and text bar code import, which is easy to learn and operate.
■ Maximum working range 1200×1200mm, it is customizable for any printing field from 300×300mm to 1200mm×1200mm.
■ Accurate load design for 30 mm mirrors, high accuracy of motor assembly, reasonable structure, very small static friction coefficient and zero offset, all ensured the best dynamic characteristics for the whole system.
■ Drives with advanced detection ability of position and speed, greatly improved the dynamic response performance and scanning speed of the whole system.
■ The whole system adopted the optimization Designing of electromagnetic compatibility, with high signal-to-noise ratio and strong anti-interference ability.
■ This scanner system solved the common problems of motor temperature drift, signal interference and zero drift, etc.
Technical Parameters
| Laser Type | 10600nm RF CO2 laser source | |
| Printing Field | 300×300mm~1200×1200mm | |
| Input Beam Size | 2.5~3mm | |
| X&Y Axes Mirrors Aperture Size | 30mm | |
| Speed | ||
| Marking Speed | 1000mm/s | |
| Positioning Speed | 1000mm/s | |
| Writing Speed | 125cps | |
| Step Response Time(1% of full scale) | 940us | |
| Step Response Time(10% of full scale) | 1500us | |
| Tracking Error Time | ≤440us | |
| Precision and Error | ||
| Linearity | 99.9% | |
| Repeatability (RMS) | <8μRad | |
| Gain Error | <5mRad | |
| Zero Offset | <5mRad | |
| Long-term Drift Over 8 Hours | <0.5mRad | |
| Scale Drift | <40PPM/℃ | |
| Zero Drift | <15μRad/℃ | |
| Power and Signal | ||
| Input Voltage | ±24VDC | |
| Rated Current | 4A | |
| Interface Signal | Digital: XY2-100 | |
| Machinery Scan Angle | ±12.5° | |
| Working Current, Temperature, Dimension | ||
| Working Temperature | 0℃~45℃ | |
| Storage Temperature | -10℃~60℃ | |
| Galvanometer Scanner Dimension | 556.5×158×188mm (L×W×H) | |
| Galvanometer Scanner Weight | ≈16.78Kg | |
| Water-Cooling System | ||
| Water Temperature | 25±3℃ | |
| Maximum water pressure | <3bar | |
| Water flow | >1L/min | |
| Water pipe specification | Outer diameter φ6mm Inner diameter φ4mm | |
Keywords: RF8330-3D-1200 Dynamic Focusing System