Product Features
■ The differential optoelectronic sensor precisely detects the motor rotor's position, offering excellent linearity, minimal drift, and high resolution as well as superior repeat positioning accuracy.
■ Precisely designed load for the 10mm lens, featuring high motor assembly accuracy, a rational structural design, minimal static friction coefficient, and negligible zero-position offset—ensuring excellent dynamic system performance.
■ The driver features advanced position and velocity feedback detection, significantly enhancing the system's dynamic response performance and scanning speed.
■ The design includes overload, overcurrent, and reverse-polarity protection, ensuring more reliable system operation.
■ The entire system features an electromagnetically compatible, optimally designed architecture with a high signal-to-noise ratio and strong anti-interference capability.
■ Addressed common issues such as galvanometer motor temperature drift, signal interference, and zero-point drift.
SG2206 Performance Technical Specifications
| Speed | |
| Marking speed (1) | 6000 mm/s |
| Positioning speed (1) | 11000 mm/s |
| Write speed (2) | 516 cps |
| Step response time (full stroke) 1% ) | <400µs |
| Step response time (full stroke) 10% ) | <1000µs |
| Tracking error | ≤164 µs |
| Accuracy and Error | |
| Linearity | 99.9% |
| Repeat positioning accuracy | <8 μRad |
| Gain Error | <5 mRad |
| Zero-point offset (batch origin error) | <5 mRad |
| Long-term drifting (continuous operation) 8 Hours) | <0.5 mRad |
| Proportional Drift | <40 PPM °C |
| Zero-point drift | <15 μRad / °C |
| Lens damage threshold | |
| K9 Matrix | 9.1 J/cm² |
| Yes Matrix | 10 J/cm² |
| Lens reflection wavelength (3) | 10600nm / 1064nm / 355nm |
| Power and Signal | |
| Input voltage | ±15VDC |
| Rated current | 2A |
| Interface Protocol | XY2-100 |
| Scan angle | ±11° |
| Operating current, temperature, dimensions | |
| Operating temperature | 0°C ~ 45°C |
| Storage temperature | -10 °C ~60 °C |
| Laser input aperture | 10mm |
| Galvanometer dimensions (length × width × height) | 118.5 × 96.5 × 94.1 mm |
| Galvanometer weight | ≈ 1.65 kg |
Note: The above parameters were measured after the engine had been running for 30 minutes.
(1) Using an F-Theta lens with a focal length of 160mm, mark 2mm-high single-line characters; (2) Using an F-Theta lens with a focal length of 160mm, it can mark single-line characters up to 1mm tall at a rate of 1mm per second. (3) Customizable special-wavelength coatings.
Keywords: SG2206 High-Speed Galvanometer
SG2206 High-Speed Galvanometer
Contact us
Classification
Product Features
■ The differential optoelectronic sensor precisely detects the motor rotor's position, offering excellent linearity, minimal drift, and high resolution as well as superior repeat positioning accuracy.
■ Precisely designed load for the 10mm lens, featuring high motor assembly accuracy, a rational structural design, minimal static friction coefficient, and negligible zero-position offset—ensuring excellent dynamic system performance.
■ The driver features advanced position and velocity feedback detection, significantly enhancing the system's dynamic response performance and scanning speed.
■ The design includes overload, overcurrent, and reverse-polarity protection, ensuring more reliable system operation.
■ The entire system features an electromagnetically compatible, optimally designed architecture with a high signal-to-noise ratio and strong anti-interference capability.
■ Addressed common issues such as galvanometer motor temperature drift, signal interference, and zero-point drift.
SG2206 Performance Technical Specifications
| Speed | |
| Marking speed (1) | 6000 mm/s |
| Positioning speed (1) | 11000 mm/s |
| Write speed (2) | 516 cps |
| Step response time (full stroke) 1% ) | <400µs |
| Step response time (full stroke) 10% ) | <1000µs |
| Tracking error | ≤164 µs |
| Accuracy and Error | |
| Linearity | 99.9% |
| Repeat positioning accuracy | <8 μRad |
| Gain Error | <5 mRad |
| Zero-point offset (batch origin error) | <5 mRad |
| Long-term drifting (continuous operation) 8 Hours) | <0.5 mRad |
| Proportional Drift | <40 PPM °C |
| Zero-point drift | <15 μRad / °C |
| Lens damage threshold | |
| K9 Matrix | 9.1 J/cm² |
| Yes Matrix | 10 J/cm² |
| Lens reflection wavelength (3) | 10600nm / 1064nm / 355nm |
| Power and Signal | |
| Input voltage | ±15VDC |
| Rated current | 2A |
| Interface Protocol | XY2-100 |
| Scan angle | ±11° |
| Operating current, temperature, dimensions | |
| Operating temperature | 0°C ~ 45°C |
| Storage temperature | -10 °C ~60 °C |
| Laser input aperture | 10mm |
| Galvanometer dimensions (length × width × height) | 118.5 × 96.5 × 94.1 mm |
| Galvanometer weight | ≈ 1.65 kg |
Note: The above parameters were measured after the engine had been running for 30 minutes.
(1) Using an F-Theta lens with a focal length of 160mm, mark 2mm-high single-line characters; (2) Using an F-Theta lens with a focal length of 160mm, it can mark single-line characters up to 1mm tall at a rate of 1mm per second. (3) Customizable special-wavelength coatings.
Keywords: SG2206 High-Speed Galvanometer