Product Features
■ Built-in 13 million pixel camera, positioning accuracy error is only 0.1mm.
■ With visual positioning module, it can automatically search for the target and calculate the marking position.
■ Adopted high-performance scanning motor which imported from the America and the international advanced photoelectric sensing technology.
■ Differential photoelectric sensor for accurate detection of motor rotor position, good linearity, lower drift, high resolution and repeat positioning.
■ Drives with advanced detection ability of position and speed, greatly improving the dynamic response performance and scanning speed of the whole system.
■ Design of overload, over-current and reverse connect protection, making the system running more reliable.
■ The whole system adopting the Optimization Designing of electromagnetic compatibility, with high signal-to-noise ratio and strong anti-interference ability.
■ Smaller scanner size, which meets the increasing industrial demands of higher precision and more compact systems.
■ This scan head can be integrated into different application systems easily. The housing is very strong and dustproof. Thus it can be used in the extremely bad environment.
Technical Parameters
| Speed | |
| Marking Speed(1) | 4000mm/s |
| Positioning Speed(1) | 7000mm/s |
| Writing Speed(2) | 301cps |
| Step Response Time(1% of full scale) | 370us |
| Step Response Time(10% of full scale) | 630us |
| Tracking Error Time | ≤202us |
| Precision and Error | |
| Linearity | 99.9% |
| Repeatability (RMS) | <8μRad |
| Gain Error | <5mRad |
| Zero Offset | <5mRad |
| Long-term Drift Over 8 Hours | <0.5mRad |
| Scale Drift | <40PPM/℃ |
| Zero Drift | <15μRad./℃ |
| Lens Damage Threshold | |
| K9 Matrix | 9.1J/cm^2 |
| Si Matrix | 10J/cm^2 |
| Wavelength(3) | 10600nm/1064nm/355nm |
| Power and Signal | |
| Input Voltage | ±15VDC |
| Rated Current | 2A |
| Interface Signal | XY2-100 |
| Max Machinery Scan Angle(4) | ±11° |
| Working Current, Temperature, Dimension | |
| Working Temperature | 0℃--45℃ |
| Storage Temperature | -10℃--60℃ |
| Aperture | 10mm |
| Galvanometer Scanner Dimension (LxWxH) | 134×96.5×120.6mm |
| Galvanometer Scanner Weight | ≈0.9Kg |
| Auto-focusing Control Parameters | |
| Measure Solution | Laser Ranging |
| Measure Resolution | 0.01mm |
| Measure Accuracy | ±0.1mm |
| Laser Wavelength | 620~690nm |
| Single Measurement Time | 0.2s |
Note: The above data are tested after 30 min warm-up
(1) With F-theta objective, F=160mm, marking 2mm height single character
(2) With F-theta objective, F=160mm, marking 1mm height single character per second
(3) Special wavelength coating film can be customized
(4) If any special requirement, customization is available. Factory default value is ±11°
Keywords: MC1603-EX Monitoring Scanning System
MC1603-EX Monitoring Scanning System
Contact us
Classification
Product Features
■ Built-in 13 million pixel camera, positioning accuracy error is only 0.1mm.
■ With visual positioning module, it can automatically search for the target and calculate the marking position.
■ Adopted high-performance scanning motor which imported from the America and the international advanced photoelectric sensing technology.
■ Differential photoelectric sensor for accurate detection of motor rotor position, good linearity, lower drift, high resolution and repeat positioning.
■ Drives with advanced detection ability of position and speed, greatly improving the dynamic response performance and scanning speed of the whole system.
■ Design of overload, over-current and reverse connect protection, making the system running more reliable.
■ The whole system adopting the Optimization Designing of electromagnetic compatibility, with high signal-to-noise ratio and strong anti-interference ability.
■ Smaller scanner size, which meets the increasing industrial demands of higher precision and more compact systems.
■ This scan head can be integrated into different application systems easily. The housing is very strong and dustproof. Thus it can be used in the extremely bad environment.
Technical Parameters
| Speed | |
| Marking Speed(1) | 4000mm/s |
| Positioning Speed(1) | 7000mm/s |
| Writing Speed(2) | 301cps |
| Step Response Time(1% of full scale) | 370us |
| Step Response Time(10% of full scale) | 630us |
| Tracking Error Time | ≤202us |
| Precision and Error | |
| Linearity | 99.9% |
| Repeatability (RMS) | <8μRad |
| Gain Error | <5mRad |
| Zero Offset | <5mRad |
| Long-term Drift Over 8 Hours | <0.5mRad |
| Scale Drift | <40PPM/℃ |
| Zero Drift | <15μRad./℃ |
| Lens Damage Threshold | |
| K9 Matrix | 9.1J/cm^2 |
| Si Matrix | 10J/cm^2 |
| Wavelength(3) | 10600nm/1064nm/355nm |
| Power and Signal | |
| Input Voltage | ±15VDC |
| Rated Current | 2A |
| Interface Signal | XY2-100 |
| Max Machinery Scan Angle(4) | ±11° |
| Working Current, Temperature, Dimension | |
| Working Temperature | 0℃--45℃ |
| Storage Temperature | -10℃--60℃ |
| Aperture | 10mm |
| Galvanometer Scanner Dimension (LxWxH) | 134×96.5×120.6mm |
| Galvanometer Scanner Weight | ≈0.9Kg |
| Auto-focusing Control Parameters | |
| Measure Solution | Laser Ranging |
| Measure Resolution | 0.01mm |
| Measure Accuracy | ±0.1mm |
| Laser Wavelength | 620~690nm |
| Single Measurement Time | 0.2s |
Note: The above data are tested after 30 min warm-up
(1) With F-theta objective, F=160mm, marking 2mm height single character
(2) With F-theta objective, F=160mm, marking 1mm height single character per second
(3) Special wavelength coating film can be customized
(4) If any special requirement, customization is available. Factory default value is ±11°
Keywords: MC1603-EX Monitoring Scanning System
