Product Features
■ Adopted the photoelectric sensors which imported from America, and owned the proprietary intellectual property rights.
■ Differential photoelectric sensor for accurate detection of motor rotor position, good linearity, lower drift, high resolution and repeat positioning.
■ Accurate load design of 30mm lens, high precision of motor assembly, reasonable structure, small static friction coefficient and zero offset, ensure the best dynamic characteristics of the system.
■ Water cooling structure is adopted to effectively control the working temperature of galvanometer.
■ Drives with advanced detection ability of position and speed, greatly improved the dynamic response performance and scanning speed of the whole system.
■ Design of overload, over-current and reverse connect protection, makes the system running more reliable.
■ The whole system adopted the optimization Designing of electromagnetic compatibility, with high signal-to-noise ratio and strong anti-interference ability.
■ This scanner system solved the common problems of motor temperature drift, signal interference and zero drift, etc.
Technical Parameters
| Speed | ||
| Marking Speed(1) | 5000mm/s | |
| Writing Speed(2) | 275cps | |
| Step Response Time(1% of full scale) | 940us | |
| Step Response Time(10% of full scale) | 1500us | |
| Tracking Error Time | ≤440us | |
| Precision and Error | ||
| Linearity | 99.9% | |
| Repeatability (RMS) | <8μRad | |
| Gain Error | <5mRad | |
| Zero Offset | <5mRad | |
| Long-term Drift Over 8 Hours | <0.5mRad | |
| Scale Drift | <40PPM/℃ | |
| Zero Drift | <15μRad/℃ | |
| Wavelength(3) | 10600nm/1064nm/355nm | |
| Power and Signal | ||
| Input Voltage | ±24VDC | |
| Rated Current | 4A | |
| Interface Signal | Digital | XY2-100 |
| Analog | ±5V | |
| Max Machinery Scan Angle(4) | ±12.5° | |
| Working Current, Temperature, Dimension | ||
| Working Temperature | 0℃--45℃ | |
| Storage Temperature | -10℃--60℃ | |
| Aperture | 30mm | |
| Galvanometer Scanner Dimension (LxWxH) | 215x171x162mm | |
| Galvanometer Scanner Weight | ≈7.87Kg | |
Note: The above data are tested after 30 min warm-up
(1) With F-theta objective, F=160mm, marking 2mm height single character
(2) With F-theta objective, F=160mm, marking 1mm height single character per second
(3) Special wavelength coating film can be customized
(4)The standard mechanical scanning angle is ±12.5°,Any special requirement available to be customized
Keywords: SG8330-G Galvo Scanner
SG8330-G Galvo Scanner
Contact us
Classification
Product Features
■ Adopted the photoelectric sensors which imported from America, and owned the proprietary intellectual property rights.
■ Differential photoelectric sensor for accurate detection of motor rotor position, good linearity, lower drift, high resolution and repeat positioning.
■ Accurate load design of 30mm lens, high precision of motor assembly, reasonable structure, small static friction coefficient and zero offset, ensure the best dynamic characteristics of the system.
■ Water cooling structure is adopted to effectively control the working temperature of galvanometer.
■ Drives with advanced detection ability of position and speed, greatly improved the dynamic response performance and scanning speed of the whole system.
■ Design of overload, over-current and reverse connect protection, makes the system running more reliable.
■ The whole system adopted the optimization Designing of electromagnetic compatibility, with high signal-to-noise ratio and strong anti-interference ability.
■ This scanner system solved the common problems of motor temperature drift, signal interference and zero drift, etc.
Technical Parameters
| Speed | ||
| Marking Speed(1) | 5000mm/s | |
| Writing Speed(2) | 275cps | |
| Step Response Time(1% of full scale) | 940us | |
| Step Response Time(10% of full scale) | 1500us | |
| Tracking Error Time | ≤440us | |
| Precision and Error | ||
| Linearity | 99.9% | |
| Repeatability (RMS) | <8μRad | |
| Gain Error | <5mRad | |
| Zero Offset | <5mRad | |
| Long-term Drift Over 8 Hours | <0.5mRad | |
| Scale Drift | <40PPM/℃ | |
| Zero Drift | <15μRad/℃ | |
| Wavelength(3) | 10600nm/1064nm/355nm | |
| Power and Signal | ||
| Input Voltage | ±24VDC | |
| Rated Current | 4A | |
| Interface Signal | Digital | XY2-100 |
| Analog | ±5V | |
| Max Machinery Scan Angle(4) | ±12.5° | |
| Working Current, Temperature, Dimension | ||
| Working Temperature | 0℃--45℃ | |
| Storage Temperature | -10℃--60℃ | |
| Aperture | 30mm | |
| Galvanometer Scanner Dimension (LxWxH) | 215x171x162mm | |
| Galvanometer Scanner Weight | ≈7.87Kg | |
Note: The above data are tested after 30 min warm-up
(1) With F-theta objective, F=160mm, marking 2mm height single character
(2) With F-theta objective, F=160mm, marking 1mm height single character per second
(3) Special wavelength coating film can be customized
(4)The standard mechanical scanning angle is ±12.5°,Any special requirement available to be customized
Keywords: SG8330-G Galvo Scanner