SG8214-EX Galvo Scanner
SG8214-EX Galvo Scanner
+
  • SG8214-EX Galvo Scanner
  • SG8214-EX Galvo Scanner

Product Features

■ Adopted the photoelectric sensors which imported from America, and owned the proprietary intellectual property rights.

■ Differential photoelectric sensor for accurate detection of motor rotor position, good linearity, lower drift, high resolution and repeat positioning.

■ Accurate load design for 14 mm mirrors, high accuracy of motor assembly, reasonable structure, very small static friction coefficient and zero offset, all ensured the best dynamic characteristics for the whole system.

■ Drives with advanced detection ability of position and speed, greatly improved the dynamic response performance and scanning speed of the whole system.

■ Design of overload, over-current and reverse connect protection, makes the system running more reliable.

■ The whole system adopted the optimization Designing of electromagnetic compatibility, with high signal-to-noise ratio and strong anti-interference ability.

■ This scanner system solved the common problems of motor temperature drift, signal interference and zero drift, etc.

Technical Parameters

Speed
Marking Speed(1) 8000mm/s
Positioning Speed 12000mm/s
Writing Speed(2) 364cps
Step Response Time(1% of   full scale) 508us
Step Response Time(10% of   full scale) 820us
Tracking Error Time ≤360us
Precision and Error
Linearity 99.9%
Repeatability (RMS) <8μRad
Gain Error <5mRad
Zero Offset <5mRad
Long-term Drift Over 8   Hours <0.5mRad
Scale Drift <40PPM/℃
Zero Drift <15μRad/℃
Wavelength(3) 10600nm/1064nm/355nm
Power and Signal
Input Voltage ±24VDC
Rated Current 4A
Interface Signal Digital XY2-100
Analog ±5V
Machinery Scan Angle(4) ±11°
Working Current, Temperature,   Dimension
Working Temperature 0℃--45℃
Storage Temperature -10℃--60℃
Aperture 14mm
Galvanometer Scanner   Dimension (LxWxH) 160x120x127mm
Galvanometer Scanner   Weight ≈4.2Kg

Note: The above data are tested after 30 min warm-up

(1) With F-theta objective, F=160mm, marking 2mm height single character

(2) With F-theta objective, F=160mm, marking 1mm height single character per second

(3) Special wavelength coating film can be customized

(4) If any special requirement, customization is available. Factory default value is ±12.5°

Keywords: SG8214-EX Galvo Scanner

SG8214-EX Galvo Scanner
SG8214-EX Galvo Scanner
+
  • SG8214-EX Galvo Scanner
  • SG8214-EX Galvo Scanner

SG8214-EX Galvo Scanner

The model galvo scanner has the good running stability, high positioning accuracy, fast marking speed, strong anti-interference ability, the overall performance of SG8214 has reached the international leading level in this field.

Classification


SG8214-EX Galvo Scanner
SG8214-EX Galvo Scanner
+
  • SG8214-EX Galvo Scanner
  • SG8214-EX Galvo Scanner

Product Features

■ Adopted the photoelectric sensors which imported from America, and owned the proprietary intellectual property rights.

■ Differential photoelectric sensor for accurate detection of motor rotor position, good linearity, lower drift, high resolution and repeat positioning.

■ Accurate load design for 14 mm mirrors, high accuracy of motor assembly, reasonable structure, very small static friction coefficient and zero offset, all ensured the best dynamic characteristics for the whole system.

■ Drives with advanced detection ability of position and speed, greatly improved the dynamic response performance and scanning speed of the whole system.

■ Design of overload, over-current and reverse connect protection, makes the system running more reliable.

■ The whole system adopted the optimization Designing of electromagnetic compatibility, with high signal-to-noise ratio and strong anti-interference ability.

■ This scanner system solved the common problems of motor temperature drift, signal interference and zero drift, etc.

Technical Parameters

Speed
Marking Speed(1) 8000mm/s
Positioning Speed 12000mm/s
Writing Speed(2) 364cps
Step Response Time(1% of   full scale) 508us
Step Response Time(10% of   full scale) 820us
Tracking Error Time ≤360us
Precision and Error
Linearity 99.9%
Repeatability (RMS) <8μRad
Gain Error <5mRad
Zero Offset <5mRad
Long-term Drift Over 8   Hours <0.5mRad
Scale Drift <40PPM/℃
Zero Drift <15μRad/℃
Wavelength(3) 10600nm/1064nm/355nm
Power and Signal
Input Voltage ±24VDC
Rated Current 4A
Interface Signal Digital XY2-100
Analog ±5V
Machinery Scan Angle(4) ±11°
Working Current, Temperature,   Dimension
Working Temperature 0℃--45℃
Storage Temperature -10℃--60℃
Aperture 14mm
Galvanometer Scanner   Dimension (LxWxH) 160x120x127mm
Galvanometer Scanner   Weight ≈4.2Kg

Note: The above data are tested after 30 min warm-up

(1) With F-theta objective, F=160mm, marking 2mm height single character

(2) With F-theta objective, F=160mm, marking 1mm height single character per second

(3) Special wavelength coating film can be customized

(4) If any special requirement, customization is available. Factory default value is ±12.5°

Keywords: SG8214-EX Galvo Scanner

Get a quote

Please leave your contact information, and our experts will reach out to you as soon as possible!

Submit